steam boiler makeup water

For some of the larger sites use area, smaller capacity gas boiler is not up to heating demand; therefore, can be designed for different volumes of gas-fired boiler with a new design concept, environmental protection and efficient image according to user needs to enter a boiler market has been widely recognized and highly valued by many customers.

Diqing in Yunnan Nonferrous Metals Co., Ltd. mainly engaged in Pulang copper mining, site selection, sales and other items. As we all know, in the copper smelting process, it consumes a lot of electricity and thermal power resources, which account for most of the hot water consumption. Combined with the actual demand Diqing company, to provide fast Boiler 1 stage electric heating hot water boiler of 2.1MW.

Industrial Boiler & Mechanical proudly sells new 3 pass firetube boilers from ZBG Boiler Company, but also has the expertise to provide on-site or in-house service and repair for 3 pass boilers from other manufacturers as well.

Standard gas boiler flue gas temperature, the abnormal temperature rise control method of treatment and a heat loss, the temperature of exhaust gas boiler 1. The state does not require a standard exhaust gas temperature, but there is a predetermined low efficiency. 2, the boiler exhaust gas at high temperature of about 120-180 degrees, the higher the exhaust gas temperature is low boiler efficiency. 3, the non-condensable exhaust gas temperature 180 degrees in the art (GB shall not less than 110 degrees) and a thermal energy conversion efficiency of the exhaust gas temperature, but also on the air coefficient and so on. Second, what factors will lead to gas-fired boiler flue gas temperature rises, there is a high gas-fired boiler flue gas temperature problems during use, gas-fired boiler flue gas temperature high will reduce the thermal efficiency of the boiler, in order to solve the exhaust gas temperature excessive problems, to understand the reasons for the high temperature exhaust gas boiler? is caused by the high temperature exhaust gas boiler does what reason? 1, the heated area ash, slagging. Heat Surface Slag cause heat deterioration, deterioration of the cooling effect of the flue gas, the exhaust gas temperature. 2, when the excess air ratio and gas boiler leakage coefficient is too large, excess air increases with the same impact. 3, gas boiler feed water temperature rises. Economizer heat transfer temperature difference decreases the exhaust gas temperature rises. 4, the fuel property. When the fuel is added water, the amount of flue gas increases, the exhaust gas temperature rises. Low volatile fuels, high ash content, so that delayed ignition, the exhaust gas temperature rises. 5, combustion and air distribution mode. Combustion air distribution mode change, the furnace may lead to shift the center of the flame, the exhaust gas temperature rises. 6, when the gas boiler furnace negative pressure is too large, the smoke quicker, increase the coefficient of air leakage, the exhaust gas temperature. 7, bottom seal gas boiler water interrupted, leakage increases and the shift of the center of the flame, the exhaust gas temperature. To understand the reasons for the high temperature exhaust gas boiler, the reason to start to solve the problem of high boiler flue gas temperature, thereby increasing the thermal efficiency of the boiler. Third, the high temperature exhaust gas boiler solution 1, see the burner power with power boiler match. Burner power is too large, the transfer of small gas flow on the line. 2, check the wind volume is too large. Adjusting the amount of the wind, the oxygen content of the combustion ratio at a reasonable gas boiler the exhaust gas temperature decreases, combustion energy. Fourth, an effective method of controlling exhaust gas heat losses of the boiler size, flue gas heat loss factors determines the size of the three: the exhaust gas temperature, excess air coefficient, and the cold air temperature. Wherein the excess air ratio of gas boiler is a major factor. Excess air ratio is too large is a large waste. A lot of cold air into the furnace, reducing the furnace temperature, combustion conditions become unstable, but also increases the flue gas volume, increased heat losses. Calculations show that when the excess air ratio is increased to 3.0 from 2.0, heat losses to 4.5%. While increasing the drum Fan burden, so power consumption increases. In order to improve the gas boiler thermal efficiency, we must pay attention to and raise awareness of the serious dangers for the high excess air ratio caused by combustion in the regulation strictly control the excess air ratio, the key to avoiding excess air furnace is reasonable with the wind and with adapted to monitor control. Monitoring means are CO2 or O2 content measurement method for measuring oxygen gas boiler is usually carried out, because the combustion of gas boiler a slight positive pressure, the seal is easy to solve the problem, the oxygen content is measured more accurately reflect the excess air coefficient values. Oxygen measurement techniques now commonly used zirconia-type oxygen analyzer constant temperature, continuous on-line measurement of the oxygen content of the flue gas. The flue gas oxygen content as a reference, the correct air-fuel ratio adjustment, a low oxygen combustion. About an effective method of controlling the size of the exhaust gas boiler heat loss, current advanced technology to automatically adjust the combustion process of oxygen combustion of PLD, followed by fine-tuning "two" that the throttle damper, to ensure normal combustion, black smoke, excess air ratio as small as possible, usually to achieve the above two points, the excess air ratio is close to the threshold. The current new generation of gas-fired boiler has been relatively safe, if you want to understand the use of gas-fired boiler, price, type and other information, please contact us.

Boiler Calculations for Steam, Hot Water and Thermal Loads

Purchase Boilers that have the Highest Gas Passes (4 or higher) Purchase Boilers that have the Highest turndown ratio, (4: 1 or higher) Operate Boilers at the correct Blowdown rate, using automation

Learn More

steam boiler makeup water - wirtshaus-im-park-kurhaus.de

Steam Boiler make up water Heating Help: The Wall adding water to a 1 pipe steam system I drain water out of my lwco every week or so and let all the rust and junk pour into a bucket. I then have to add water to the boiler, not a lot, but some to get it back to the mark I have on my sight glass.

Learn More

Boiler water - Wikipedia

Boiler water is liquid water within a boiler, or in associated piping, pumps and other equipment, that is intended for evaporation into steam. The term may also be applied to raw water intended for use in boilers, treated boiler feedwater, steam condensate being returned to a boiler, or boiler blowdown being removed from a boiler.

Learn More

A Quick Tutorial on the Mechanics of Steam Boiler Systems

May 22, 2018 · Its important to note that the pressure range of the boiler and the end use of the steam dictate makeup water quality, which can range from raw water, to softened water, to high purity de-mineralized water. Boiler Options. Boilers come in a wide range of sizes and shapes and can be classified based on design, operating pressure, and fuel type.

Learn More

Makeup Water - an overview | ScienceDirect Topics

The receiver and evaporator makeup water treatment system shall be determined according to the quality of raw water, the quality standard of feed or boiler water, the makeup water rate, the blowdown rate, equipment and drug supply conditions, and effluent discharge as well as other factors after conducting comprehensive technical and economic comparisons.

Learn More

What Is a Boiler Feed Water Treatment System and How Does It

Sep 26, 2016 · Makeup water, or the water replacing evaporated or leaked water from the boiler, is first drawn from its source, whether raw water, city water, city-treated effluent, in-plant wastewater recycle (cooling tower blowdown recycle), well water, or any other surface water source. Coagulation and chemical precipitation

Learn More

Steam boiler Automatic & Manual Water Feeder Valves

If your steam boiler has only a manual valve for adding water, until you know the system's rate of water usage, you should check the water level at least once a week during the heating season. You'll want to add water whenever the sight glass shows that the water level has dropped to the "add" mark and you should always see some water in the sight glass.

Learn More

Common Steam-Boiler-Replacement Mistakes

Aug 13, 2015 · The condensate pump will feed water into the boiler whether the boiler needs any or not. This was acceptable with the old, large boilers because the water level was not as crucial as the new ones. If the system required make-up water, water was fed directly into the boiler through a float valve located on the boiler.

Learn More

Boiler feed water - Lenntech

Boiler feed water. As steam is produced, dissolved solids become concentrated and form deposits inside the boiler. This leads to poor heat transfer and reduces the efficiency of the boiler. Dissolved gasses such as oxygen and carbon dioxide will react with the metals in the boiler system and lead to boiler corrosion.

Learn More

Reverse Osmosis Improves Boiler Efficiency Water Technology

Jan 16, 2017 · Reverse Osmosis Improves Boiler Efficiency. Commercial boilers account for 120,000 units that provide heat and hot water for office buildings, hospitals, and universities. The average commercial boiler is smaller in size than the typical industrial boiler at 9.6 million Btu per hour (10,000 pounds of steam per hour),

Learn More

boiler water feed issue - YouTube

Oct 13, 2010 · interesting issue with potential for flooding a steam boiler. interesting issue with potential for flooding a steam boiler. Steam boiler auto water feeder issue and replacment - Duration:

Learn More

boiler makeup water calculation CFBC Boiler Manufacturer

an average boiler efficiency of 82%, and make-up water temperature of 55°F. The water and sewage A simple calculation indicates that energy in the condensate can be more than 10% of the total steam reduced its boiler makeup water. Reduce Boiler Blowdown Water Go Solar California CA.gov

Learn More

BLOWDOWN CALCULATION FOR BOILER - Altret

BLOWDOWN CALCULATION FOR BOILER This term is the most important term in boiler operation and monitoring. The parameters of the blow down are to be maintained for particular boiler. This is due to the fact that water inside the boiler gets continuously evaporated due to steam generation. Concentration of dissolve solid, inside the drum

Learn More

Check & Vent Valves - Steam Boiler & Hot Water Supplies

Durabla and Bonomi Check Valves | Boiler Supplies. WATER HAMMER is the generation and effect of high pressure shock waves (transients) in relatively incompressible fluids. Water hammer is caused by the shock waves that are generated when a liquid is stopped abruptly in a pipe by an object such as a valve disc.

Learn More

Residential Steam Boiler Basics - The Spruce