size of 6ton boiler

Excessive moisture content in steam size of 6ton boiler steam boiler steam system of hazard in the event of excessive steam water content, will constitute a steam system damage. Steam boiler system in major damage to wet steam are: 1, water droplets suspended in the steam pipeline corrosion can drop life. Replacement pipe is not as long as the cost of materials and labor, and you want some pipeline closed for repairs, it will bring some loss of production. 2, the steam contained in the steam boiler system, water droplets can damage (corrosion of the valve seat, the valve body) the control valve, so that the effect of lost, and eventually damage the quality of the goods. 3, the steam contained in the water droplets will collect on the exterior of the heat exchange water into a thin film growth. 1mm thick film of water corresponding to 60mm of iron / steel sheet or 50mm thick copper plate heat transfer, this layer of water film to change the appearance of the heat exchange coefficient of the heat exchanger, the heating time is extended, decreased production capacity. 4, wet steam with decreased total gas heat exchange device power. Water droplets occupy valuable space means boring full steam vapor will be taken to effect heat transfer. 5, the wet steam in a steam boiler system in concealing mixture of fouling in the heat exchange outer, heat exchange will decrease power. Heat exchange outer layer scale is not the same thickness, which causes different thermal expansion, a crack will occur on the outer heat exchanger. The material is heated from the condensate mixed with leak cracks, loss soiled condensate, will bring about high costs. 6, the wet steam concealing mixture control valve and steam trap fouling, will affect the operation of the valve, to add the cost of repairs. 7, wet steam boiler system, steam heating the product mixture enters the concealing eruption of steam directly, if the product requires high hygiene standards fit, becomes contaminated waste products will not be sold. 8, some processing technology is not wet steam, wet steam will eventually affect the quality of the goods. 9, in addition to the influence of the apparent power of the heat exchange outer wet steam, wet steam concealing will constitute excess water trap and condensate recovery system overload. Traps overload will condensate back, if condensed water vapor occupies space, which will reduce production capacity of processing equipment, during this period will ultimately affect the quality of the goods. 10, water droplets in the steam, air and other gases can affect the accuracy of the flow meter measuring the flow rate. Dry steam coefficient is 0.95, the configuration of the flow measurement error of 2.6%; and boring coefficient is 8.5, the measurement error will reach 8%. Means for supplying steam flow is accurate reliable data to an operator, the production technology for the process control in the best condition and to maximize the production of power, steam and water droplets so that all can not be accurately performed.

School project uses hot water size of 6ton boiler which type is better? As China increasingly improve the ecological environment protection, air emissions requirements become more stringent, the boiler must be innovative aspects of the lower row, the major boiler manufacturers have engaged in a more environmentally clean fuel gas boiler market.

PM2.5 is frequently mentioned in recent years, and its main premise was that the formation of NOx, according to the latest research results show in Beijing, PM2.5 and NOx emissions due to the formation of more than 50% of the total proportion of PM2.5. Because of a large area of ​​coal to gas projects in recent years, the country's use of gas-fired size of 6ton boiler more than 50 million units in the Beijing area, gas boiler emissions will soon exceed the vehicle, as the primary sources of NOx in Beijing, so Beijing EPA first proposed the strict NOx emission standards: Beijing new boiler to perform emission limit of 30 mg / standard cubic meter for boilers with high-pollution fuel combustion zone ban, the implementation of emission limit 80 mg / standard cubic meter . The standard is much higher than the European emission standards for boilers, to the world's most demanding emissions standards in Southern California to move closer to the boiler.

The daily operation of the size of 6ton boiler adjustment (regulation Part 2): In a large boiler operating parameters change in the magnitude of the situation, should be used "quick adjustment" and "over-regulation" approach, the parameters can change its trend as soon as possible, the "coarse . " Especially when handling accident, to adjust the water level, particular attention should be. Case of an accident, such as "load shedding" "boiler fire" and the like, when the level variation is very large, and because the "false impact level," the rate of change quickly, operators requires rapid response and regulating. And if the mother controls the water supply system, several furnace influence each other, plus the usual low water pressure, in case of an accident, several furnaces at the same time the water level changes, "over water" is serious, and therefore more in the "coarse" They should coordinate with each other to pass on. Avoid artificially adjusting improper expansion of the accident. E.g. "turbine load rejection" and the boiler because the water level regulating improper fire; for level adjustment improper full of water when the "boiler fire"; even when a boiler blower trip underlayer powder machine speed caused by too much air duct blockage and the like.

Proper sizing of Boiler Feedwater System

That is why it is so important to size a feedwater system so that it has the capability of maintaining the proper water level in your boiler. PROPERLY SIZED A properly sized feedwater system will have a tank adequately sized to feed your boiler and pumps selected to deliver that water at the correct rate and pressure.

Learn More

6 Ton Gas Fired Boiler Quotation- Boiler

How much is a 6 ton natural gas boiler? Taking 6 ton boiler with1.25 MPa as an example, only the boiler proper is about 100,000 RMB, adding to auxiliary equipment, a set of 6 tons natural gas boilers is quoted at about 200,000 RMB(ex-factory price). If NOx is required to be discharged below 30 mg/m³, then low-nitrogen burners are needed.

Learn More

What is a boiler horsepower [BHP], a unit of power measurement

Boiler horsepower is a power measurement unit. One Boiler Horsepower (1BHP) is equal to a bolier thermal output of 33 475 BTU/h (British Thermal Units per Hour) or 9.81055407 kW (Kilowatts). This is the energy rate required to evaporate 34.5 lb (pounds) or 15.648936765 kg (kilograms) of fresh water at 212 °F (degrees Fahrenheit) or 100 °C (Celsius) in one hour (1h).

Learn More

Boiler Size 10 Ton - jagdreisenpolen.de

201818-China Fully Automatic Double Drums Coal Fired Boiler 6ton 10ton, Find details about China Coal Fired Boiler 6ton 10ton, 6t Coal Boiler from Get a qoute boiler 10 ton for price srilanka boiler sprices

Learn More

dimension of 2 ton oil gas steam boiler

oil gas fired boiler | Boiler. 2019-2-11 · Boiler is the Asia's leading manufacturer of oil gas boilers,industrial steam boilers,hot water boilers,firetube boilers, watertube boilers,high/low pressure boilers as well as high efficiency low nitrogen condensing boilers and horizontal/vertical heating boilers for commercial and industrial markets.

Learn More

1-10 tons steam boiler, 1.4-7 MW hot water boiler,1-10 tons

Product dimensions and equipment levels are tailored to the customer's individual needs, and a wide range of options are available, and the thermal efficiency of this boiler can be up to 98%. 5.6 MW, 4 ton, 6 ton,10 Ton- Boiler

Learn More

Boiler Piping Flow & Pipe Sizing | HVAC Hydronics

Boiler Piping Flow & Pipe Sizing - Copper and Steel Pipe Flow Rates and Characteristics of Piping in Hot Water Boiler Loops Hot water boiler pipe sizing.

Learn More

Boiler Sizing | Weil-McLain

Name Description Boiler Replacement Guide Step-By-Step Procedures For Properly Sizing Hot Water And Steam Replacement Boilers For Homes And Small Commercial Buildings Boiler Sizing | Weil-McLain Skip to main content

Learn More

Boiler (power generation) - Wikipedia

A boiler or steam generator is a device used to create steam by applying heat energy to water.Although the definitions are somewhat flexible, it can be said that older steam generators were commonly termed boilers and worked at low to medium pressure (72,000 kPa or 1290 psi) but, at pressures above this, it is more usual to speak of a steam generator.

Learn More

Boiler Capacity - Engineering ToolBox

Boiler load - the capacity of a steam boiler - is often rated as boiler horse powers, lbs of steam delivered per hour, or BTU. Lbs Steam delivered per Hour. Large boiler capacities are often given in lbs of steam evaporated per hour under specified steam conditions. BTU - British Thermal Units

Learn More

Steam Boiler | Working principle and Types of Boiler

Aug 22, 2018 · Steam boiler efficiency depends upon the size of boiler used. A typical efficiency of steam boiler is 80% to 88%. A typical efficiency of steam boiler is 80% to 88%. Actually there are some losses occur like incomplete combustion, radiating loss occurs from steam boiler surrounding wall, defective combustion gas etc.

Learn More

What is the size of the coal in the boiler of a thermal power

Oct 13, 2017 · It depends on what type of coal you are using. But generally coal shall be around 50 mm (diamwter approx) afte crushing in crusher which is again powdered or pulverised in the mill to the size of 70% through 200 mesh (50 microns) before admitting

Learn More

Boiler Sizing - How to Choose the Right Size Boiler

Sep 03, 2016 · Boiler output is measured in Kw (kilowatt) Its basically just a way of measuring how much output the boiler has. To give you an example of how much heating power you need, in the late 90s a common boiler of choice for a 4 bedroom house with a cylinder was an Ideal Classic HE 15.

Learn More

6ton Big Size Wood Block Fired Boiler To Generate Steam - Buy

6ton Big Size Wood Block Fired Boiler To Generate Steam, Find Complete Details about 6ton Big Size Wood Block Fired Boiler To Generate Steam,Boiler To Generate Steam,Wood Block Fired Boiler,6ton Boiler To Generate Steam from Boilers Supplier or Manufacturer-Qingdao East Power Industry Equipment Co., Ltd.

Learn More

Boiler Horsepower - Engineering ToolBox

Boiler horsepower - a power unit from the 19 th-20 th centuries - was used to rate the capacity of a boiler to deliver steam to steam engines.. A common definition of one boiler horsepower is the amount of energy required to produce 34.5 pounds (15.65 kg) of steam per hour at pressure and temperature 0 psig (0 bar) and 212 o F (100 o C) - with feed water at pressure 0 psig and temperature 212 o F.

Learn More